T-cell engager
Blinatumomab-induced T cell–B cell engagement was measured over time in PBMCs and patient bone marrow.
Science and evidence
Interact-omics maps physically interacting cells from multicolour flow-cytometry data. InterAcTec applies that measurement principle to defined therapeutic and translational questions, combining deep immune phenotyping with lineage-resolved interaction mapping.

40 markers. One high-dimensional readout.
Cell identities & states
Physical interactions
What is measured
Interacting cells can pass the laser as one event carrying the marker sets of both cell types. Conventional workflows often exclude these events as doublets.
The framework combines scatter characteristics with co-expression of mutually exclusive lineage markers to identify and assign those events to a cell-type pair. Acquisition must follow suitable guidelines and controls; not every existing flow-cytometry dataset is compatible.
One cell, one event. Effector markers only.
Counted as a singlet
One cell, one event. Target markers only.
Counted as a singlet
Two cells pass the laser as one event: both marker sets, and a shifted forward-scatter ratio (FSC-A/FSC-H).
Usually gated out as a “doublet”
→ Resolved as an interacting pair
Full-spectrum flow cytometry
Study-specific panels combine lineage-defining and cell-state markers. The result is a multidimensional protein profile alongside an interaction map of the cell lineages present in the sample.
State-marker measurements add biological context. They do not imply that every possible state-to-state interaction is independently resolved.
40-plex describes the panel-design capability shown here. The Nature Methods study demonstrated optimized 24/25-plex assays; performance is established for each study panel and sample system.
High-dimensional protein readout
40 markers, measured together.
40-plex
Measurement principle
01 · Encounter
Effector and target cells share the sample. The question is which of them actually engage — and how that changes under treatment.
02 · Engage
The readout focuses on physically interacting pairs and on how their frequency shifts between defined conditions.
03 · Read out
A conjugate passes the cytometer as one event carrying both marker sets. Scatter signature and marker co-expression make it countable and classifiable.
04 · Compare
Interaction frequencies per cell-type pair line up across compounds, concentrations, donors or time points.
Workflow
01
Use a compatible cell suspension such as a co-culture, PBMC sample or other liquid sample.
02
Run multicolour flow cytometry with a suitable panel, controls and the framework’s acquisition guidelines.
03
Identify interacting cells through scatter characteristics and mutually exclusive lineage-marker combinations.
04
Compare interaction frequencies per cell-type pair across the study’s defined conditions.
Published evidence
Vonficht D, et al. Ultra-high-scale cytometry-based cellular interaction mapping. Nature Methods 22, 1887–1899 (2025).
Blinatumomab-induced T cell–B cell engagement was measured over time in PBMCs and patient bone marrow.
Anti-CD19 CAR-T cell engagement with B-cell targets was resolved alongside other interacting pairs.
Antigen-specific T cell–APC engagement and signalling inside interacting T cells were demonstrated.