Skip to content

Science and evidence

Measure the cellular engagement behind the endpoint.

Interact-omics maps physically interacting cells from multicolour flow-cytometry data. InterAcTec applies that measurement principle to defined therapeutic and translational questions, combining deep immune phenotyping with lineage-resolved interaction mapping.

Full-spectrum flow cytometry40-plex
3D schematic of a spectral flow cytometer with a sample tube and a magnified glass flow cell, showing single cells and an interacting cell pair passing the laser.

40 markers. One high-dimensional readout.

Cell identities & states

Physical interactions

Schematic 3D visualization
Compatible flow cytometry, study-specific panels and acquisition controls.

What is measured

Cell pairs that pass the cytometer together.

Interacting cells can pass the laser as one event carrying the marker sets of both cell types. Conventional workflows often exclude these events as doublets.

The framework combines scatter characteristics with co-expression of mutually exclusive lineage markers to identify and assign those events to a cell-type pair. Acquisition must follow suitable guidelines and controls; not every existing flow-cytometry dataset is compatible.

Effector cell

One cell, one event. Effector markers only.

Counted as a singlet

Target cell

One cell, one event. Target markers only.

Counted as a singlet

Engaged pair

Two cells pass the laser as one event: both marker sets, and a shifted forward-scatter ratio (FSC-A/FSC-H).

Usually gated out as a “doublet”

→ Resolved as an interacting pair

Schematic visualization · dashed line = laser interrogation pointMethod: Vonficht et al., Nature Methods 2025

Full-spectrum flow cytometry

High-plex phenotyping, plus physical interactions.

Study-specific panels combine lineage-defining and cell-state markers. The result is a multidimensional protein profile alongside an interaction map of the cell lineages present in the sample.

State-marker measurements add biological context. They do not imply that every possible state-to-state interaction is independently resolved.

40-plex describes the panel-design capability shown here. The Nature Methods study demonstrated optimized 24/25-plex assays; performance is established for each study panel and sample system.

High-dimensional protein readout

40 markers, measured together.

40-plex

Illustrative 40-marker expression matrixForty columns represent a marker panel, with eight example immune lineages as rows. Colours indicate illustrative low-to-high signal, not experimental data or a fixed panel.Each column = one markerCD4 TCD8 TBNKcMononcMonocDCpDC0140LowHighMarker signal · illustrative
200+
Cell phenotypes & functional states by panel design
>25
Lineage-resolved cell-interaction types by panel design
Illustrative data layout, not experimental results. Marker selection, phenotyping depth and interaction resolution depend on the study panel.

Measurement principle

From physical engagement to a comparative readout.

  1. 01 · Encounter

    Two populations. One question.

    Effector and target cells share the sample. The question is which of them actually engage — and how that changes under treatment.

    Schematic: a field of effector cells (teal) and target cells (violet); one effector–target pair in the centre is about to meet.
    Schematic visualization
  2. 02 · Engage

    Physical engagement becomes the signal.

    The readout focuses on physically interacting pairs and on how their frequency shifts between defined conditions.

    Schematic: the central pair is in contact and the contact zone is highlighted, while a second pair elsewhere is merely adjacent without a contact zone.
    Schematic visualization
  3. 03 · Read out

    Every engaged pair becomes an event.

    A conjugate passes the cytometer as one event carrying both marker sets. Scatter signature and marker co-expression make it countable and classifiable.

    Schematic: the engaged pair becomes a single event in a two-marker plot. Effector-only and target-only events lie along the axes; interacting events carry both markers.
    Schematic visualization
  4. 04 · Compare

    Conditions become comparable.

    Interaction frequencies per cell-type pair line up across compounds, concentrations, donors or time points.

    Illustrative chart, not experimental results: interacting-event frequencies arranged in columns for a control and three candidates.
    Illustrative data — not experimental results

Workflow

A new readout on familiar infrastructure.

  1. 01

    Prepare

    Use a compatible cell suspension such as a co-culture, PBMC sample or other liquid sample.

  2. 02

    Acquire

    Run multicolour flow cytometry with a suitable panel, controls and the framework’s acquisition guidelines.

  3. 03

    Map

    Identify interacting cells through scatter characteristics and mutually exclusive lineage-marker combinations.

  4. 04

    Compare

    Compare interaction frequencies per cell-type pair across the study’s defined conditions.

Published evidence

Demonstrated across therapeutic and immune settings.

Vonficht D, et al. Ultra-high-scale cytometry-based cellular interaction mapping. Nature Methods 22, 1887–1899 (2025).

T-cell engager

Blinatumomab-induced T cell–B cell engagement was measured over time in PBMCs and patient bone marrow.

CAR-T cells

Anti-CD19 CAR-T cell engagement with B-cell targets was resolved alongside other interacting pairs.

Immune responses

Antigen-specific T cell–APC engagement and signalling inside interacting T cells were demonstrated.